Godrej Enterprises Group

Common problems

How to ascertain the sequence of terminals of any compressor?

Measure the resistance of windings as under:

  • Insert the black test lead into the common terminal of the multimeter/ohm meter & red test lead into an terminal. 
  • Set the function switch to the Ohm range.
  • Connect the test leads to terminal 1 & terminal 2 of the compressor & note the value. 
  • Connect the test leads to terminal 1 & terminal 3 of the compressor & note the value. 
  • Connect the test leads to terminal 2 & terminal 3 of the compressor & note the value. 

Now you are ready to identify the compressor terminal sequence: 

  • The highest reading indicates the total of the run + start winding resistance. 
  • 2nd highest reading indicates the start winding. 
  • The lowest reading indicates the run-winding.

You can now locate the S, C, and R terminals of the compressor.

Was this helpful?

Couldn’t find what you were looking for?